Electric Contact Temperature Gauge – Capillary Stem

Model 512
for Industrial Applications

Availability: Upon Request – OEM Orders

The production process of Items marked as “Upon Request…” starts after receiving the order and usually needs 3 weeks or more.

In industrial processes, there are times when you need to read the temperature values and at the same time have the ability to alter electric circuits (open/close) at desired set values. In case the media demands a stainless steel instrument, then InstruMate model 512 electric contact pressure gauges are the right choice. Contact-Mate 512 is a heavy duty Gas Actuated with switch contacts of snapaction type.
InstruMate electric contact gauges open or close electric circuits depending on the position of the indicating pointer. So if temperature value monitoring and switching application are needed at the same time, InstruMate Electric switch gauges come in handy.
Having them put into correct application, InstruMate Electric Contact Gauges with their robust design are a reliable choice for switching functions (normally closed, normally open, and change-over contacts).
Setpoint for contacts are adjusted easily by the use of a key supplied with the product and free movement of the value-pointer is guaranteed regardless of the setpoints.

Applications

  • Circuit switching and plant monitoring
  • Controlling industrial processes
  • Making or breaking electric circuits in a plant
  • Power plants, chemical, petrochemical and machine
    building
  • Use as electric alarm contacts
  • Do not use for medias that are viscous, crystallizing.
  • Do not use in hazardous or explosion prone areas. Check
    Model 514 instead

Special Features

  • Easily adjustable contacts
  • Long lifespan and possibility of filling the instrument
  • Full stainless steel construction with heavy duty tube
  • Reliable reading and switching
  • Various switch contact options

Specification

Nominal Sizes in mm: 100, 160
Scale Ranges in °C: -60…+40, -30…+50, -20…+80 , 0…60, 0…100, 0…120, 0…160, 0…200, 0…250, 0…300, 0…400, 0…500, 0…600, 0…650
Pressure limitation at stem: Max. 20 bar
Temperature Element: Gas actuated bourdon tube
Temperature Limitations: Storage & Transport: -20…+60 °C
Ambient: 0…40 °C
Accuracy: Class 2 per EN13190
Window: Instrument Glass
Case: SS304
Capillary Lengths (m): 1, 3, 6, 10
Stem: Material: SS316
Diameter: 10 mm (option 10mm,12mm)